• Home
  • View Cart
  • Login
  • Register for FREE
  • Contact us
  • Information
    • Welcome !:

      • About the site
      • Membership
      • Website FAQ's

      Interaction:

      • Photos

      Downloads:

      • European Certs
      • IAB Certs
      • EPA Manuals
      • Detailed Drawings
      • Brochures
      • Bedtime Reading
    • Interesting Links:

      • Interesting sites

      Exclusive Septic Guides:

        Environmental Complaints:

        • See something Say something
        • Archived complaints

        How to Videos:

        • For Everyone
        • For SiteAssessors
        • For Partners

        Newsletters:

        • Wastewater TIMES
    • Shop
      • Welcome !:

        • Shop Homepage
        • Great Discounts
        • Payment Options

        Partners:

        • Sell your products

        Irish Septic Companies:

        • Product Categories ::

          • Air Pumps/Air Blowers
          • Calming/Stilling Chamber
          • Distribution Box Risers
          • Distribution Boxes
          • Flow Divider
          • Percolation/Leaching Chambers
          • Pressurised Distribution System
          • Risers & Lids
          • Sand EPA Cop
          • Septic Tank Filters
          • Septic Tanks
          • Soil T/P
          • Submersible Pumps
          • Treatment Units / Bio Units
          • UV - Filters
          • Vent Odour Filters
      • Forums
          • Forums Home

          Forum Categories:

          • EPA Code Of Practice ...
          • Percolation Areas...
          • T/P Test Results...
          • Discussions broken down by individual Local A...
          • General Discussion...
          • General Photos...
          • GSI Groundwater Protection Responses...
          • Wetlands & Reedbeds...
          • EPA 2000 Site Characterisation Form...
          • SR6 1991...
        • Latest Threads:

          • recommendation for pump to pump raw wastewate...
          • logistically difficult site - options?...
          • How often should one Desludge a Secondary WWT...
          • Air blowers...
          • Study on the hydraulic loading rates on the a...
          • Looking for good value septic tank...
          • Maintenance contracts...
          • Biorock aeration unit...
          • Reed Bed Design...
          • Dropped Manholes from Septic Tank to Percolat...
      • Blog
          • All Blogs

          Our Bloggers:

          • Kevin J Murray
          • Tim Clifford
          • Feidhlim Harty
          • EPA Ireland
          • Happening Elsewhere
        • Last few blogs:

          • Irish Biounit Parameters
          • Zero Discharge Willow Facilities, Construction Seminar.
          • EPA Clarify sizing of Tertiary Filters
          • Certified cost effective concrete tank : BioTank with SGW Percolations
          • International Symposium on Domestic Wastewater Treatment and Disposal Systems
      • Services
        • Request a Quote:

          • for a Site Assessment
          • for a Septic Tank
          • For a Bio Unit
          • for Tank Desludging

          Services 4 HomeOwner:

          • Find an Expert
          • Maintenance
        • Services 4 SiteAssessor:

          • Pressurised Network PDF Generator
          • Site Suitablity Report PDF Generator
          • Request a Specification
          • Your website 4 free

          Services 4 Partners:

          • Advertising packages
          • Request Live Lead
          • List your products
      • Home
      • Blog
      • August BioPro Wastewater Treatment System

      SiteAssessor.com Blog

      August BioPro Wastewater Treatment System

      by Tim Clifford on Friday, 04 November 2011
      Oh no. Not another “bio” system. That’s what Terry Hutt thought when he named his company last year, after seeing a need for an affordable cost alternative solution to Ireland’s wastewater woes.

      The last year has seen tremendous changes in the way Ireland views wastewater management and local authorities, companies and newer developments have been put under the microscope as to the treatment of effluent and the ability to safely return it to the environment. Terry, a Canadian born architect has been practising architecture in Ireland for 7 years and with the downturn in the economy and the building bust making it harder to make a living, decided to change his focus to providing an affordable alternative to the traditional methods of wastewater treatment and raise the bar in the final level of treatment the system provides for one off homes to purpose built systems of up to 5000 people population.

      Their partner, August IR is a German - Lithuanian company that has been developing and manufacturing high level wastewater treatment systems for over 12 years, and has specific patented technology that treats the wastewater to a very high level. It isn’t rocket science, but it does require a PhD, and the two men that developed the system for August are both professors in bio technology. Terry met with the owner, Philionis August, and saw a product that would fit in very well with the Irish Ethos. Thus a partnership was borne.

      Some of the finer points;
      CE Marking. All units are serialized and conform to the most recent European standard for pre-packaged wastewater treatment systems. August plants undergo a specific testing to “raise the bar” by adopting a rigorous regime known as the Veolia Protocol for their conformity. This adds a higher level of testing taking the unit to 300% capacity for weeks and also dormancy for 3-4 weeks ensuring the units will work under very different conditions, replicating highs and lows.
      ISO 9001, ISO 14001 – The Company adheres to strict process controls which ensure best manufacturing practises.

      Another AT-8

      Odour. None of it. The system operates silently and with no odours.


      Mechanical Cleaning. The units incorporate an ingenious screening mechanism which does not allow any harmful particulars to enter into the internal portions of the system that could harm it. The basket design is easily cleaned out and is handy for the layman to use.

      High Grade of Effluent. The outflow from the unit has been treated to a high degree: BOD: 7mg/l, SS: 10 mg/l, Total P: 2mg/l,  NH4-N: 2mg/l
      A six person unit only has 1.5m³ of sludge production for the year, making it low maintenance and easy to clean.

      The Warranty. All the units carry a ten year guarantee with a two year guarantee on the blower, which is the only mechanical part on the system. The blower uses about 270kwh annually for a six person system, and only operates half the day at specific timed intervals.


      The Price. Starting at an introductory price of only €2450 for the small holiday home, the units are under priced for what they do. Good things do come in small packages, however you don’t always have to pay a fortune for a quality product.


      AT-6 Closed

      Advantages of August BioPro patented wastewater treatment plants:
      • High-performance, removes nitrogen and phosphorus;
      • Uses no chemical substances;
      • No offensive odour given off;
      • Insensitive to peak flows;
      • Low power consumption (4PE uses 208 kWh/per annum);
      • Low generation of excess sludge (1 cub. m./per annum of excess sludge 4PE)
      • Occupies less space and spoils no aesthetic scenery, making the most of the available space;
      • Easy-to-use, cost-effective installation and maintenance;
      • Can be left free of wastewater for 30 days +, great for planning long-term trips and holidays;
      • Can operate under any weather conditions – due to the biological processes running in the plant, the contents of the tanks do not freeze even under a very low temperature;
      • Conforms to the highest ecological standards and produces no impact on nature.



      Futhermore,
      • The August Biopro plant can be Installed and commissioned within 1 working day.
      • Wastewater treatment starts the moment the plant is started (no down time).
      • The water treated in August Biopro wastewater treatment plants could be reused as service water.


      August BioPro is committed to helping people address their wastewater needs at a reasonable price. Emerging applications for factories, cattle marts, commercial developments, and local authorities will see a rise in BioPro’s ability to apply their product and make a difference. There is no project too small or too large so please feel free to give Terry a call.

      August BioPro Ireland
      Contact; Terry Hutt
      Phone 01 5479318
      This e-mail address is being protected from spambots. You need JavaScript enabled to view it
      www.biopro.ie




      AT-6
      AT-8
      Tags
      bio unitproducts


      Comments



      Leave your comments

      It's simple to leave a comment !

      Login here if you already have a SiteAssessor.com account.
      Register here if you wish to create a SiteAssessor.com account

      Or simply connect with a service below :

      bio sand

      Popular Blog/News Tags

      Water EPA river pollution Donegal Wicklow Monaghan Cavan Disaster Galway E. coli public water supply IRDA Garavogue Sligo Ballina Gormley Kiltimagh Mayo

      Latest Blog Comments

      John Canno said
      "I absolutely agree that people can't afford to pay any more charges or taxes. However, I still believe that water charges represent an ...
      Your Water Bill for 2012 ...3 weeks ago
      Tim Clifford said
      Hi Mark, I have uploaded the National Annex NA (normative) Requirements for small wastewater treatment systems (packaged and/or site ...
      Why are only certain WWTU...3 weeks ago
      Eddy Boyle said
      All very well to start charging us for water but have given us no time to upgrade our water system in our houses, for instance my toilet...
      Your Water Bill for 2012 ...3 weeks ago
      Tim Clifford said
      Hi Mark, I don't know, let me email a few lads and get back to you. Tim
      Why are only certain WWTU...4 weeks ago
      Mark Mc Connell said
      Hi Tim Is the primary source document which details the Irish National Annex Table NA1 and Table NA2 available on line. Regards, ...
      Why are only certain WWTU...4 weeks ago

      Follow us on Twitter

      • over 12k page views of latest wastewater times newsletter http://t.co/Bp9otRua
        3 weeks ago
      • @kencurtin a decent second best to killarney national park #upthekingdom
        3 weeks ago
      • @Fmenvironmental send en certs to info@siteassessor.com and ill upload them for the community. Thx tim
        4 weeks ago
      • Why certain "bio units" suitable for use in Ireland http://t.co/wPixYUep
        1 month ago
      • Latest Wastewater Times just published. If you are interested in wastewater you will enjoy this read http://t.co/wPixYUep
        1 month ago